Critical Procedure - Synchronised cardioversion

Back to Critical Procedures - Index page
Home
For all procedures, ask yourself, 'does this need to be done 'now vs later'? And should this be done by 'me vs someone else?' Very often the answers will be 'now' and 'me' - so read on!

Synchronised cardioversion

 

Description

How to perform synchronised cardioversion for 'unstable' tachycardias.

Indications

VT_strip
VT
SVT
strip
SVT

'Unstable' tachycardias - see ACLS Tachycardia algorithm 2015.

In ACLS, 'unstable' is defined as the presence of one or more of

  • hypotension
  • new altered level of consciousness
  • signs of shock
  • ischaemic chest pain
  • new or worsening cardiac failure

Contraindications

This procedure is not for pulseless VT or for VF.  Both of these should be treated with unsynchronized defibrillation.

Cardioversion of atrial fibrillation is contraindicated unless the patient is significantly unstable and needs rhythm control immediately.  Try to avoid cardioversion if:

  • rhythm is AF and it has been present for more than 48 hours
  • rhythm is AF with onset within 48 hours but with a CHADS2 risk score of 2 or more (risk of atrial thrombus and therefore stroke).
In these situations, rate control may be preferable in terms of avoiding stroke risk from cardioversion.


Equipment

Monitor/defibrillator.
IV cannula
Resuscitation equipment

Procedure

Cardioversion electrode position image
Pad positions for cardioversion
R wave synchronisation

 

  • the defibrillation pads will probably already be in place, if not, place them on the patients chest in the positions indicated on the pads
  • if there is time and the patient can comprehend, explain to the patient what you propose to do and get consent
  • explain to the team what you are going to do
  • sedation is necessary if the patient is awake, depending on the urgency of the situation
    • brief sedation with propofol is usually adequate - alternatively midazolam could be used
    • evidence suggests no need for adding an opiate (which increases the hypotension and apnoea risk)
  • select 'Sync' on the monitor and ensure it is marking the R waves (this is to avoid delivering a shock on the T wave which can precipitate VF)
  • select the energy level.

    Initial energy levels in Joules
    VT (monomorphic)
    100 100
    AF 120-200 200
    Atrial flutter / SVT
    50-100 50-100
    VT (polymorphic eg. Torsades)
    Unsyncrhonized 200
    Unsyncrhonized 200


  • ensure everyone is clear, before briefly re-checking the monitor and pressing and holding the Shock button.  Say 'you're clear, I'm clear, still in (whichever rhythm), shocking....'
  • you may need to hold the 'Shock' button for a brief time to allow the defibrillator to deliver the shock at the correct, synchronised time
  • if tachycardia persists, increase the energy by perhaps 50 J or more, re-select Sync, and repeat the process

Potential pitfalls

Improperly positioned or adhered defibrillation pads.
Inadequate safety when delivering a shock.
Not checking that the defib is 'synched' every shock
Not holding the Shock button long enough for a shock to be delivered.

"Plan B"

Synchronised cardioversion is usually successful.
In case of failure review pharmacological options and/or attempt to discuss with a cardiologist.

Back to Critical Procedures - Index page
Home
Last modified: Friday, 14 August 2020, 2:45 PM